Artigos em Conferências
This paper proposes an analytical strategy based on mathematical models to address the load dispatch problem in thermal power plants, simultaneously considering economic and environmental criteria. Using the computational tool LabVIEW, the study develops a multi-objective model that minimizes operational costs and pollutant emissions (SO₂ and NOₓ) while meeting energy demand. The results demonstrate the approach's effectiveness across different load scenarios, highlighting solutions that balance energy efficiency and environmental impact reduction.
RAIMUNDO EDNEY DOS SANTOS AZEVEDO, UBIRATAN HOLANDA BEZERRA, JANDECY CABRAL LEITE, MANOEL SOCORRO SANTOS AZEVEDO, VILMAR DOMINGOS DA SILVA NETO
Conferência: ALTAE.The drilling process of a printed circuit board can be one of the most time consuming steps in the whole manufacturing process if not optimized. The optimization of the drilling sequence can be a very time consuming process if a brute force approach is to be done, due to the combinational nature of the problem. This renders the solution almost infeasible for more than 25 drilling points, yielding more than 10 possible combinations. The present paper presents an implementation of a genetic algorithm applied to the optimization of the drilling process of a printed circuit boards. The algorithm was tested with a practical printed circuit board, yielding in a mild but appreciable enhancement.
PAULO AUGUSTO SHERRING DA ROCHA JUNIOR, MARIA EMÍLIA DE LIMA TOSTES
Conferência: XI SIMPÓSIO BRASILEIRO DE AUTOMAÇÃO INTELIGENTE - SBAI.Este trabalho avalia a margem da estabilidade de tensão na SE Rurópolis 230 kV do sistema Tramoeste da Eletrobras Eletronorte, usando medições locais de sincrofasores de tensão e corrente. A avaliação se baseia na identificação dos parâmetros do equivalente de Thevenin (tensão e impedância) "vistos" da SE-Rurópolis 230 kV. O problema da instabilidade de tensão é estimado pela comparação entre a impedância de Thevenin (impedância à montante) e a impedância da carga (impedância à jusante). A monitoração da "distância" relativa entre essas duas impedâncias indica a proximidade do máximo carregamento do sistema à jusante da barra monitorada, consequentemente dando, com adequada precisão, a proximidade do colapso de tensão. Testes preliminares foram realizados usando medições reais de fasores de tensão e corrente da SE-Rurópolis 230 kV, as quais foram obtidas a partir do Open PDC (Phasor Data Concentrator) da Eletrobrás Eletronorte, com uma taxa de amostragem de 10 fasores/s. Com a obtenção desses dados históricos avaliou-se o comportamento da SE-Rurópolis 230 kV, no que diz respeito à margem de estabilidade de tensão frente a diferentes condições operacionais do Sistemas Interligado Nacional (SIN), para os seguintes três estudos de caso: 1) Avaliação da margem da estabilidade de tensão levando em consideração o carregamento do sistema; 2) Avaliação da margem de estabilidade de tensão levando em consideração a participação dos geradores da UHE-Tucuruí; e 3) Avaliação da margem de estabilidade de tensão frente a grandes perturbações no SIN. O amadurecimento da abordagem proposta poderá levar a desenvolvimentos futuros que tendem a remediar problemas detectado.
BERNARD CARVALHO BERNARDES, JOAO PAULO ABREU VIEIRA, UBIRATAN HOLANDA BEZERRA, GLAUCO NERY TARANTO, DJALMA MOSQUEIRA FALCÃO, TATIANA MARIANO LESSA DE ASSIS, JOAQUIM AMÉRICO PINTO MOUTINHO BECK
Conferência: XXII SNPTEE.Este artigo visa apresentar uma metodologia de cálculo de equivalentes dinâmicos de sistemas de potência utilizando algoritmos genéticos, e avaliar a estabilidade transitória da interligação Tucuruí-Manaus-Macapá do subsistema norte do SIN (Sistema Interligado Nacional). O método consiste em minimizar o erro absoluto entre as potências do sistema completo e do seu modelo equivalente. Para validação da metodologia proposta, foram utilizados dois sistemas elétricos, um de pequeno porte, conhecido como sistema de duas áreas do IEEE e outro de grande porte, o SIN, considerando a interligação Tucuruí-Manaus-Macapá, substituindo os subsistemas Sudeste/Centro-Oeste/Sul e Nordeste por equivalentes dinâmicos. O método proposto apresentou resultados bastante satisfatórios com relação à coerência dos geradores, além de reduzir significativamente o tempo computacional de simulação no programa ANATEM.
PITTHER NEGRÃO, DIONE J. ABREU VIEIRA, BERNARD C. BERNARDES, JOAO PAULO ABREU VIEIRA, UBIRATAN HOLANDA BEZERRA
Conferência: XXII SNPTEE.O uso de recursos renováveis, como a geração fotovoltaica (GFV), desponta como solução para o atendimento de localidades na Amazônia. Assim, diante do uso da GFV conectada à rede, este trabalho apresenta uma metodologia de avaliação do impacto do aumento da penetração da geração fotovoltaica (GFV) em redes primárias isoladas e supridas por usinas a diesel, considerando altos níveis de penetração. Com a integração da GFV na rede, em função da radiação solar e temperatura ambiente, será avaliado o perfil de tensão, a perda ativa, a potência gerada pela usina a diesel, o consumo de combustível e o nível de CO2.
CLÁUDIO GONÇALVES, JOÃO P. ABREU VIEIRA, DIONE J. ABREU VIEIRA, MARIA E. LIMA TOSTES, BERNARD C. BERNARDES, UBIRATAN H. BEZERRA
Conferência: Seminário Nacional de Produção e Transmissão de Energia Eletrica..Este artigo visa apresentar uma metodologia de cálculo de equivalentes dinâmicos de sistemas de potência utilizando algoritmos genéticos, e avaliar a estabilidade transitória da interligação Tucuruí-Manaus-Macapá do subsistema norte do SIN (Sistema Interligado Nacional). O método consiste em minimizar o erro absoluto entre as potências do sistema completo e do seu modelo equivalente. Para validação da metodologia proposta, foram utilizados dois sistemas elétricos, um de pequeno porte, conhecido como sistema de duas áreas do IEEE e outro de grande porte, o SIN, considerando a interligação Tucuruí-Manaus-Macapá, substituindo os subsistemas Sudeste/Centro-Oeste/Sul e Nordeste por equivalentes dinâmicos. O método proposto apresentou resultados bastante satisfatórios com relação à coerência dos geradores, além de reduzir significativamente o tempo computacional de simulação no programa ANATEM.
PITTHER NEGRÃO, DIONE J. ABREU VIEIRA, BERNARD C. BERNARDES, JOAO PAULO ABREU VIEIRA, UBIRATAN HOLANDA BEZERRA
Conferência: XXII SNPTEE.This paper presents a genetic algorithm-based approach that determines aggregated dynamic models of SCIG- based wind farm and their corresponding electrical and mechanical parameters. The technique is based on a multi- objective optimal formulation solved by a genetic algorithm to minimize the error of the active power and reactive power between the equivalent single-generator model and the investigated wind farm. The influence of the wind farm equivalent model on the dynamic behavior of synchronous generators in the power system, are also investigated by using the proposed method. The approach is tested on a 10MW wind farm consisting of 4 wind turbines (2 x 2MW and 2 x 3MW) with SCIGs integrated on the IEEE 14-bus power system. The results obtained using the detailed dynamic model for the windfarm representation are compared against those obtained with the proposed aggregated model to evaluate the accuracy and the computational cost of the proposed mod
F. MONTEIRO, W. D. OLIVEIRA, D.S. GAIA, J. P. A. VIEIRA, U. H. BEZERRA
Conferência: XV GLAGTEE.Este trabalho apresenta uma metodologia para monitoramento da segurança estática em tempo real de sistemas elétricos utilizando árvore de decisão. A partir de exaustivas simulações off-line via Anarede foi gerada a base de dados relacionada aos aspectos da segurança, para as diversas condições operacionais, para identificar os atributos do sistema e fornecer um modelo de predição rápido e preciso para aplicação em tempo real utilizando as medições do sistema Scada/EMS. A metodologia foi testada no sistema elétrico do Amapá, cujos resultados mostraram ser uma importante ferramenta para avaliação da segurança estática no centro de operação do sistema.
BENEDITO G. D. RODRIGUES, DIEIGO S. GAIA, BERNARD C. BERNARDES, DIONE J. A. VIEIRA, WERBESTON D. DE OLIVEIRA, JOÃO PAULO A. VIEIRA, UBIRATAN H. BEZERRA, VILSON CASTRO
Conferência: X SIMPASE.. Previous works has demonstrated the feasibility of palm oil application as fuel for compression engines as well as others vegetable oils. Such oils can be used without chemical transformations requiring only be filtered and neutralized, both simple processes, and they have high heating values similar to diesel oil. Problems already identified are related with its high viscosity at room temperature and requirement for larger residence time than diesel fuel to complete its combustion reaction. The first problem has been solved with oil pre-heating before high pressure injection pump inlet and there are available systems to perform this task. To the second problem (longer residence time) all proposed approach to solve it rely on keep high temperature in the combustion chamber and accelerate the chemical kinetics in such way that the engine available time for combustion is bigger than the fuel required residence time. It implies that the engine can operate with vegetable oils only at high loads, being replaced by diesel oils at medium and low loads. This problem has been report on all experiments using direct injection compressed engines. Indirect combustion engines have a pre-combustion chamber that is kept always at high temperature independent of the shaft load. Therefore, it is supposed that such engines are able to operate with vegetable oils along their full range of operating load. This work tested an indirect injection engine assembled as part of a 20 kVA generator set, (genset) and the results compared with those of direct injection engine. Palm Oil was used as fuel and the genset received instrumentation to measure the fuel temperature and its flow rate, eludd gas temperature at exit of combustion chamber, electric power produced and gas emitted composition (CO and NOx,). Similar data was obtained for the genset operating with pure diesel oil for comparison. In order to quantify the inlet amount of energy the diesel oil and palm oil were submitted to high heating value and ultimate analysis. Results showed that indirect injection engine operating with palm oil have an increasing on specific consumption fuel as well as CO and NOx concentration and small drop on exhaustion gases temperature, compared with direct injection engine consuming palm oil for the same load percentage.
RICARDO SILVA PEREIRA, MANOEL FERNANDES MARTINS NOGUEIRA, MARIA EMÍLIA DE LIMA TOSTES
Conferência: Brazilian Congress of Thermal Sciences and Engineering.This paper presents a comprehensive study showing the impacts of different doubly fed induction generator (DFIG) wind turbines control modes on long-term voltage stability. The study considers fixed voltage control and power factor control modes. The analyses also consider the dynamic models of Over Excitation Limiter (OEL) and On Load Tap Changers (OLTC) combined with static and dynamic loads using time domain simulations. A hypothetical network is used for the scenario of 20% load increase. The impact of each control strategy is studied and the resulting change in long-term system stability is quantified, as well as the interactions between OLTC and OEL equipments. The results show that the manner in which DFIGs are operated will have a significant impact on system stability.
R. R. LONDERO, C. M. AFFONSO, J. P. A. VIEIRA, U. H. BEZERRA
Conferência: IEEE PES ISGT Europe.